Devices for dry roofs / HEXAONDE Air Treuil
HEXAONDE PASS is a skylight for dry roofs designed for overhead lighting and roof access.
HEXAONDE PASS features a smoke vent built into a polyester profiled upstand reinforced with tinted fibreglass (steel or aluminium cladding: RAL 9010, fibre cement: RAL 7040).
| Reference | Dimension (Low shafts) | Dimension (High shafts) | SLU m² | SGO | Weight | Angle d'ouverture | |
| C100 | 120 x 120 | 100 x 100 | 1,00 | 1,00 | 49 | 110 |
| C120 | 140 x 140 | 120 x 120 | 1,44 | 1,44 | 52 | 110 |
| C140 | 160 x 160 | 140 x 140 | 1,96 | 1,96 | 60 | 110 |
| C160 | 180 x 180 | 160 x 160 | 2,56 | 2,56 | 75 | 110 |
| R100-150 | 120 x 170 | 100 x 150 | 0,49 | 0,49 | 52 | 110 |
| R100-200 | 120 x 220 | 100 x 200 | 0,64 | 0,64 | 63 | 110 |
| R140-200 | 160 x 220 | 140 x 200 | 1,20 | 1,20 | 86 | 110 |
Aluminium cover
- Insulated, light transmission = 0%, heat loss coefficient U = 1.18 W/m².K.
- Non-insulated, light transmission = 0%.
- Opal/Transparent (M4), light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
- Opal/Transparent (M4 non-dripping) light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
- HEXACHOC 1200 Joules, Transparent/Opal (M4 non-dripping) light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
- Opal (B-S1 d0), light transmission = 62%, heat loss coefficient U = 3.1 W/m².K.
- Transparent (B-S1 d0), light transmission = 85%, heat loss coefficient U = 3.1 W/m².K.
- Calor control (B-S1 d0), light transmission = 55%, heat loss coefficient U = 3.1 W/m².K.
- Grey opaque, light transmission = 0%, heat loss coefficient U = 3.1 W/m².K.
- Opal (B-S2 d0), light transmission = 51%, heat loss coefficient U = 2.8 W/m².K.
- Transparent (B-S2 d0), light transmission = 74%, heat loss coefficient U = 2.4 W/m².K.
- Calor control (B-S2 d0), light transmission = 46%, heat loss coefficient U = 2,4 W/m².K.
- Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).
- Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.
Painted profiled upstand
- The outer edge of the profiled upstand is protected by a standard RAL 9010 (white) gelcoat; optional painting in most colours in the RAL range (specify in the order).
Profile type
Profile type
Profile type
Profile type
Single flap
Winch opening
- Opening is controlled by a winch box.
Griddle
- Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).
Painted griddle
- Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.
Painted profiled upstand
- The outer edge of the profiled upstand is protected by a standard RAL 9010 (white) gelcoat; optional painting in most colours in the RAL range (specify in the order).
Profile type
- Aluminium cladding.
- Fibre cement.
- Sandwich cladding.
- Steel cladding.
Single flap
Winch opening
- Opening is controlled by a winch box.