ReferenceDimension (Low shafts)Dimension (High shafts)SLU m²SGOWeightAngle d'ouverture
C100120 x 120100 x 1001,001,0049110
C120140 x 140120 x 1201,441,4452110
C140160 x 160140 x 1401,961,9660110
C160180 x 180160 x 1602,562,5675110
R100-150120 x 170100 x 1500,490,4952110
R100-200120 x 220100 x 2000,640,6463110
R140-200160 x 220140 x 2001,201,2086110

Aluminium cover

  • Insulated, light transmission = 0%, heat loss coefficient U = 1.18 W/m².K.
  • Non-insulated, light transmission = 0%.

Double dome  Download PV fire  Download PV 1200j

  • Opal/Transparent (M4), light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
  • Opal/Transparent (M4 non-dripping) light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
  • HEXACHOC 1200 Joules, Transparent/Opal (M4 non-dripping) light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.

PCA 10 mm  Download PV fire

  • Opal (B-S1 d0), light transmission = 62%, heat loss coefficient U = 3.1 W/m².K.
  • Transparent (B-S1 d0), light transmission = 85%, heat loss coefficient U = 3.1 W/m².K.
  • Calor control (B-S1 d0), light transmission = 55%, heat loss coefficient U = 3.1 W/m².K.
  • Grey opaque, light transmission = 0%, heat loss coefficient U = 3.1 W/m².K.

PCA 16 mm  Download PV fire

  • Opal (B-S2 d0), light transmission = 51%, heat loss coefficient U = 2.8 W/m².K.
  • Transparent (B-S2 d0), light transmission = 74%, heat loss coefficient U = 2.4 W/m².K.
  • Calor control (B-S2 d0), light transmission = 46%, heat loss coefficient U = 2,4 W/m².K.

Griddle  Download PV 1200j

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).

Painted griddle  Download PV 1200j

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.

Painted profiled upstand

  • The outer edge of the profiled upstand is protected by a standard RAL 9010 (white) gelcoat; optional painting in most colours in the RAL range (specify in the order).

Profile type

  • Steel cladding.

Profile type

  • Fibre cement.

Profile type

  • Sandwich cladding.

Profile type

  • Aluminium cladding.

Single flap

  • Single-leaf device

Winch opening

  • Opening is controlled by a winch box.

Griddle

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).

Painted griddle

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.

Painted profiled upstand

  • The outer edge of the profiled upstand is protected by a standard RAL 9010 (white) gelcoat; optional painting in most colours in the RAL range (specify in the order).

Profile type

  • Aluminium cladding.
  • Fibre cement.
  • Sandwich cladding.
  • Steel cladding.

Single flap

  • Single-leaf device

Winch opening

  • Opening is controlled by a winch box.