HEXACOIF MoP (Double Flap, Pneumatic opening/closing) is a smoke and heat ventilator (NSHEV) for adaptation or renovation and is designed for overhead lighting and smoke extraction.

HEXACOIF DoP features: a 150mm or 300mm high (depending on performance) galvanised steel upstand compatible with any type of existing upstand (concrete, steel, wood) without modification of the existing upstand.

   
ReferenceDimension (Low shafts)Dimension (High shafts)SLU m²Upstand AFA 280mmSGOWeightAngle d'ouverture
C180 Plus180 x 180180 x 1803,242,433,2414890  
C180 Eco180 x 180180 x 1803,241,623,2411990  
C180 Standard180 x 180180 x 1803,242,223,2413590  
C200 Plus200 x 200200 x 2004,003,004,0016490  
C200 Eco200 x 200200 x 2004,001,764,0013390  
C200 Standard200 x 200200 x 2004,002,684,0014190  
R120-240 Standard120 x 240120 x 2402,882,002,8812990  
R120-240 Plus120 x 240120 x 2402,882,162,8814190  
R120-240 Eco120 x 240120 x 2402,881,622,8811890  
R120-250 Standard120 x 250120 x 2503,002,083,0013290  
R120-250 Plus120 x 250120 x 2503,002,253,0014590  
R120-250 Eco120 x 250120 x 2503,001,663,0012290  
R120-300 Plus120 x 300120 x 3003,602,703,6016490  
R120-300 Eco120 x 300120 x 3003,601,843,6013990  
R120-300 Standard120 x 300120 x 3003,602,483,6014090  
R150-250 Plus150 x 250150 x 2503,752,813,7516090  
R150-250 Eco150 x 250150 x 2503,751,853,7513290  
R150-250 Standard150 x 250150 x 2503,752,543,7514690  
R150-300 Standard150 x 300150 x 3004,503,024,5016590  
R150-300 Plus150 x 300150 x 3004,503,384,5019390  
R150-300 Eco150 x 300150 x 3004,502,044,5015190  
R160-250 Standard160 x 250160 x 2504,002,694,0014190  
R160-250 Plus160 x 250160 x 2504,003,004,0016690  
R160-250 Eco160 x 250160 x 2504,001,904,0013790  
R160-300 Eco160 x 300160 x 3004,802,094,8015590  
R160-300 Standard160 x 300160 x 3004,803,194,8016990  
R160-300 Plus160 x 300160 x 3004,803,614,8018590  
R180-250 Plus180 x 250180 x 2504,503,394,5017690  
R180-250 Eco180 x 250180 x 2504,501,974,5014590  
R180-250 Standard180 x 250180 x 2504,502,994,5016090  
R180-300 Plus180 x 300180 x 3005,404,095,4019690  
R180-300 Eco180 x 300180 x 3005,402,155,4016390  
R180-300 Standard180 x 300180 x 3005,403,555,4017990  
R200-250 Standard200 x 250200 x 2505,003,295,0017190  
R200-250 Plus200 x 250200 x 2505,003,785,0018590  
R200-250 Eco200 x 250200 x 2505,002,005,0015390  
R200-300 Standard200 x 300200 x 3006,003,906,0018690  
R200-300 Plus200 x 300200 x 3006,004,566,0020390  
R200-300 Eco200 x 300200 x 3006,002,166,0016990  

Reference Activation pressure Thermal fuse cartridge weight in grams
PCA CAI/DD PCA CAI/DD
SL 250 SL 550 SL 250 SL 550 SL 250 SL 550 SL 250 SL 550
Vol. total Pression (bar) Vol. total Pression (bar) Vol. total Pression (bar) Vol. total Pression (bar) Gramme (g.) Gramme (g.) Gramme (g.) Gramme (g.)
C180 Plus 1,14101,14151,14101,141620202020  
C180 Eco 1,14101,14151,14101,141620202020  
C180 Standard 1,14101,14151,14101,141620202020  
C200 Plus 1,3101,3181,3121,32020402040  
C200 Eco 1,3101,3181,3121,32020402040  
C200 Standard 1,3101,3181,3121,32020402040  
R120-240 Standard 0,62100,62170,62110,621920202020  
R120-240 Plus 0,62100,62170,62110,621920202020  
R120-240 Eco 0,62100,62170,62110,621920202020  
R120-250 Standard 0,62100,62180,62110,622020202020  
R120-250 Plus 0,62100,62180,62110,622020202020  
R120-250 Eco 0,62100,62180,62110,622020202020  
R120-300 Plus 0,62110,62210,62130,622320202020  
R120-300 Eco 0,62110,62210,62130,622320202020  
R120-300 Standard 0,62110,62210,62130,622320202020  
R150-250 Plus 0,86100,86160,86110,861820202020  
R150-250 Eco 0,86100,86160,86110,861820202020  
R150-250 Standard 0,86100,86160,86110,861820202020  
R150-300 Standard 0,86100,86190,86120,862120202020  
R150-300 Plus 0,86100,86190,86120,862120202020  
R150-300 Eco 0,86100,86190,86120,862120202020  
R160-250 Standard 1,02101,02161,02101,021820202020  
R160-250 Plus 1,02101,02161,02101,021820202020  
R160-250 Eco 1,02101,02161,02101,021820202020  
R160-300 Eco 1,02101,02191,02121,022120402040  
R160-300 Standard 1,02101,02191,02121,022120402040  
R160-300 Plus 1,02101,02191,02121,022120402040  
R180-250 Plus 1,14101,14191,14121,142120402040  
R180-250 Eco 1,14101,14191,14121,142120402040  
R180-250 Standard 1,14101,14191,14121,142120402040  
R180-300 Plus 1,14121,14221,14141,142520402040  
R180-300 Eco 1,14121,14221,14141,142520402040  
R180-300 Standard 1,14121,14221,14141,142520402040  
R200-250 Standard 1,3121,3221,3142,041620402040  
R200-250 Plus 1,3121,3221,3142,041620402040  
R200-250 Eco 1,3121,3221,3142,041620402040  
R200-300 Standard 1,3142,04171,3172,041820404040  
R200-300 Plus 1,3142,04171,3172,041820404040  
R200-300 Eco 1,3142,04171,3172,041820404040  

Aluminium cover

  • Insulated, light transmission = 0%, heat loss coefficient U = 1.18 W/m².K.
  • Non-insulated, light transmission = 0%.

PCA 10 mm  Download PV fire

  • Opal (B-S1 d0), light transmission = 62%, heat loss coefficient U = 3.1 W/m².K.
  • Transparent (B-S1 d0), light transmission = 85%, heat loss coefficient U = 3.1 W/m².K.
  • Calor control (B-S1 d0), light transmission = 55%, heat loss coefficient U = 3.1 W/m².K.
  • Grey opaque, light transmission = 0%, heat loss coefficient U = 3.1 W/m².K.

PCA 16 mm  Download PV fire

  • Opal (B-S2 d0), light transmission = 51%, heat loss coefficient U = 2.8 W/m².K.
  • Transparent (B-S2 d0), light transmission = 74%, heat loss coefficient U = 2.4 W/m².K.
  • Calor control (B-S2 d0), light transmission = 46%, heat loss coefficient U = 2,4 W/m².K.

C02 thermofuse

  • Rated to trip at 93°C (as standard and factory-assembled, delivered with CO2 cartridge).

Double flap

  • Double-leaf device

Electrical switches

  • They can be connected to an indicating panel showing the installation's opening position and functional status.

Flat part of upstand

  • 80mm flat measurements as standard. Special dimensions: COIFFANTE SP (panels between 60 and 150mm).

Griddle  Download PV 1200j

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).

Insulated adaptable upstand

  • Adaptable upstand with 15mm thick insulation board (as standard) covered with corner-welded galvanised steel.

Painted griddle  Download PV 1200j

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.

Painted upstand

  • The inside of the upstand can be painted. RAL tint to be specified in the order.

Part-opening electrical daily ventilation

  • Partial ventilation 300mm with a cylinder (220V)

SL 250 snow load

  • Regulatory snow load for smoke extraction in buildings located between 0 and 400m in altitude. SL 250 = 25 daN/m².

SL 550 snow load

  • To exceed regulatory requirements. SL 500 minimum for buildings located between 400 and 800m in altitude.

C02 thermofuse

  • Rated to trip at 93°C (as standard and factory-assembled, delivered with CO2 cartridge).

Double flap

  • Double-leaf device

Electrical switches

  • They can be connected to an indicating panel showing the installation's opening position and functional status.

Flat part of upstand

  • 80mm flat measurements as standard. Special dimensions: COIFFANTE SP (panels between 60 and 150mm).

Griddle

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).

Insulated adaptable upstand

  • Adaptable upstand with 15mm thick insulation board (as standard) covered with corner-welded galvanised steel.

Painted griddle

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.

Painted upstand

  • The inside of the upstand can be painted. RAL tint to be specified in the order.

Part-opening electrical daily ventilation

  • Partial ventilation 300mm with a cylinder (220V)

SL 250 snow load

  • Regulatory snow load for smoke extraction in buildings located between 0 and 400m in altitude. SL 250 = 25 daN/m².

SL 550 snow load

  • To exceed regulatory requirements. SL 500 minimum for buildings located between 400 and 800m in altitude.