HEXASTEEL LAME TPI (CO2 opening/closing) is a smoke and heat ventilator (NSHEV) with insulated aluminium blades for all types of roof designed for daily ventilation and smoke extraction.

HEXASTEEL LAME TPI features: motorised blades powered by a pneumatic cylinder and gas springs (200mm travel). The aluminium blades pivot on an aluminium outer fixed frame and are surrounded by windshields.

   
ReferenceDimension (Low shafts)Dimension (High shafts)Number of louversUpstand AFA 280mmSGOWeight
1000-16561000 x 16561000 x 1656131,111,6673
1000-21561000 x 21561000 x 2156171,442,16100
1031-10311031 x 10311031 x 103180,711,0663
1156-11561156 x 11561156 x 115690,901,3472
1281-12811281 x 12811281 x 1281101,101,6481
1400-21561400 x 21561400 x 2156172,023,02121
1406-14061406 x 14061406 x 1406111,321,9891
1500-26561500 x 26561500 x 2656212,673,98147
1500-30311500 x 30311500 x 3031243,054,55162
1531-15311531 x 15311531 x 1531121,572,34102
1656-16561656 x 16561656 x 1656131,842,74116
1781-17811781 x 17811781 x 1781142,133,17127
1906-19061906 x 19061906 x 1906152,433,63139

No filling for this product

Aluminium blades

  • Insulated unwrought aluminium blades. Heat loss coefficient U = 1.27 W/m².K.

C02 thermofuse

  • Rated to trip at 93°C (as standard and factory-assembled, delivered with CO2 cartridge).

Electrical switches

  • They can be connected to an indicating panel showing the installation's opening position and functional status.

Painted upstand

  • The inside of the upstand can be painted. RAL tint to be specified in the order.

Pneumatic opening

  • Opening is controlled by a pneumatic cylinder.

SL 250 snow load

  • Regulatory snow load for smoke extraction in buildings located between 0 and 400m in altitude. SL 250 = 25 daN/m².

SL 500 snow load

  • Regulatory snow load for smoke extraction in buildings located between 400 and 800m in altitude. SL 500 = 50 daN/m².

Upstand for PVC membrane

  • Upstand with factory-assembled unbacked insulation board compatible with a PVC membrane. Option to attach a strip of galvanised or PVC-coated steel at the top of the skylight frame.

Aluminium blades

  • Insulated unwrought aluminium blades. Heat loss coefficient U = 1.27 W/m².K.

C02 thermofuse

  • Rated to trip at 93°C (as standard and factory-assembled, delivered with CO2 cartridge).

Electrical switches

  • They can be connected to an indicating panel showing the installation's opening position and functional status.

Painted upstand

  • The inside of the upstand can be painted. RAL tint to be specified in the order.

Pneumatic opening

  • Opening is controlled by a pneumatic cylinder.

SL 250 snow load

  • Regulatory snow load for smoke extraction in buildings located between 0 and 400m in altitude. SL 250 = 25 daN/m².

SL 500 snow load

  • Regulatory snow load for smoke extraction in buildings located between 400 and 800m in altitude. SL 500 = 50 daN/m².

Upstand for PVC membrane

  • Upstand with factory-assembled unbacked insulation board compatible with a PVC membrane. Option to attach a strip of galvanised or PVC-coated steel at the top of the skylight frame.