Roof access

Devices for dry roofs / HEXAONDE Pass

Roof access - HEXAONDE Pass
Download
HEXAONDE AIR winch is a skylight for dry roofs designed for overhead lighting and daily ventilation.

HEXAONDE AIR winch features a smoke vent built into a polyester profiled upstand reinforced with tinted fibreglass (steel or aluminium cladding: RAL 9010, fibre cement: RAL 7040).

   
ReferenceDimension (Low shafts)Dimension (High shafts)SLU m²SGOWeightAngle d'ouverture
C100120 x 120100 x 1001,001,004290
C120140 x 140120 x 1201,441,444590
C140160 x 160140 x 1401,961,964290
R100-150120 x 170100 x 1501,501,505290

Aluminium cover

  • Insulated, light transmission = 0%, heat loss coefficient U = 1.18 W/m².K.
  • Non-insulated, light transmission = 0%.

Double dome  Download PV fire  Download PV 1200j

  • Opal/Transparent (M4), light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
  • Opal/Transparent (M4 non-dripping) light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
  • HEXACHOC 1200 Joules, Transparent/Opal (M4 non-dripping) light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.

PCA 10 mm  Download PV fire

  • Opal (B-S1 d0), light transmission = 62%, heat loss coefficient U = 3.1 W/m².K.
  • Transparent (B-S1 d0), light transmission = 85%, heat loss coefficient U = 3.1 W/m².K.
  • Calor control (B-S1 d0), light transmission = 55%, heat loss coefficient U = 3.1 W/m².K.
  • Grey opaque, light transmission = 0%, heat loss coefficient U = 3.1 W/m².K.

PCA 16 mm  Download PV fire

  • Opal (B-S2 d0), light transmission = 51%, heat loss coefficient U = 2.8 W/m².K.
  • Transparent (B-S2 d0), light transmission = 74%, heat loss coefficient U = 2.4 W/m².K.
  • Calor control (B-S2 d0), light transmission = 46%, heat loss coefficient U = 2,4 W/m².K.

Ladder rest bar

  • For resting all types of ladder on the upstand (delivered factory-assembled).

Manual opening

  • Opening is controlled by a 1.5m, 2m, 3m or 4m long brace.

Opening griddle  Download PV 1200j

  • Square 15 x 15, 120mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).

Opening painted griddle  Download PV 1200j

  • Square 15 x 15, 120mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.

Painted profiled upstand

  • The outer edge of the profiled upstand is protected by a standard RAL 9010 (white) gelcoat; optional painting in most colours in the RAL range (specify in the order).

Profile type

  • Steel cladding.

Profile type

  • Fibre cement.

Profile type

  • Sandwich cladding.

Profile type

  • Aluminium cladding.

Roof access bracket

  • For easier, safer roof access (delivered factory-assembled).

Single flap

  • Single-leaf device

Ladder rest bar

  • For resting all types of ladder on the upstand (delivered factory-assembled).

Manual opening

  • Opening is controlled by a 1.5m, 2m, 3m or 4m long brace.

Opening griddle

  • Square 15 x 15, 120mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).

Opening painted griddle

  • Square 15 x 15, 120mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.

Painted profiled upstand

  • The outer edge of the profiled upstand is protected by a standard RAL 9010 (white) gelcoat; optional painting in most colours in the RAL range (specify in the order).

Profile type

  • Aluminium cladding.
  • Fibre cement.
  • Sandwich cladding.
  • Steel cladding.

Roof access bracket

  • For easier, safer roof access (delivered factory-assembled).

Single flap

  • Single-leaf device