Print
Devices for renovation and adaptation / HEXACOIF Air Manuel
| Download |
HEXACOIF AIR manual is a skylight for adaptation or renovation designed for overhead lighting and daily ventilation.
HEXACOIF AIR manual features: a 150mm high galvanised steel upstand compatible with any type of existing upstand (concrete, steel, wood) without modification of the existing upstand.
| Reference | Dimension (Low shafts) | Dimension (High shafts) | SLU m² | SGO | Weight | |
|---|---|---|---|---|---|---|
| C50 | 50 x 50 | 50 x 50 | 0,25 | 0,25 | 18 | |
| C60 | 60 x 60 | 60 x 60 | 0,36 | 0,36 | 21 | |
| C70 | 70 x 70 | 70 x 70 | 0,49 | 0,49 | 26 | |
| C80 | 80 x 80 | 80 x 80 | 0,64 | 0,64 | 28 | |
| C85 | 85 x 85 | 85 x 85 | 0,72 | 0,72 | 31 | |
| C100 | 100 x 100 | 100 x 100 | 1,00 | 1,00 | 35 | |
| C120 | 120 x 120 | 120 x 120 | 1,44 | 1,44 | 45 | |
| C130 | 130 x 130 | 130 x 130 | 1,69 | 1,69 | 52 | |
| C140 | 140 x 140 | 140 x 140 | 1,96 | 1,96 | 63 | |
| C150 | 150 x 150 | 150 x 150 | 2,56 | 2,56 | 72 | |
| C160 | 160 x 160 | 160 x 160 | 2,25 | 2,25 | 82 | |
| C180 | 180 x 180 | 180 x 180 | 3,24 | 3,24 | 98 | |
| C200 | 200 x 200 | 200 x 200 | 4,00 | 4,00 | 110 | |
| R50-100 | 50 x 100 | 50 x 100 | 0,50 | 0,50 | 27 | |
| R70-100 | 70 x 100 | 70 x 100 | 0,70 | 0,70 | 33 | |
| R100-140 | 100 x 140 | 100 x 140 | 1,40 | 1,40 | 51 | |
| R100-150 | 100 x 150 | 100 x 150 | 1,50 | 1,50 | 53 | |
| R100-200 | 100 x 200 | 100 x 200 | 2,00 | 2,00 | 61 | |
| R140-200 | 140 x 200 | 140 x 200 | 2,80 | 2,80 | 91 |
Aluminium cover
- Insulated, light transmission = 0%, heat loss coefficient U = 1.18 W/m².K.
- Non-insulated, light transmission = 0%.
Double dome Download PV fire Download PV 1200j
- Opal/Transparent (M4), light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
- Opal/Transparent (M4 non-dripping) light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
- HEXACHOC 1200 Joules, Transparent/Opal (M4 non-dripping) light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
PCA 10 mm Download PV fire
- Opal (B-S1 d0), light transmission = 62%, heat loss coefficient U = 3.1 W/m².K.
- Transparent (B-S1 d0), light transmission = 85%, heat loss coefficient U = 3.1 W/m².K.
- Calor control (B-S1 d0), light transmission = 55%, heat loss coefficient U = 3.1 W/m².K.
- Grey opaque, light transmission = 0%, heat loss coefficient U = 3.1 W/m².K.
PCA 16 mm Download PV fire
- Opal (B-S2 d0), light transmission = 51%, heat loss coefficient U = 2.8 W/m².K.
- Transparent (B-S2 d0), light transmission = 74%, heat loss coefficient U = 2.4 W/m².K.
- Calor control (B-S2 d0), light transmission = 46%, heat loss coefficient U = 2,4 W/m².K.
Flat part of upstand
- 80mm flat measurements as standard. Special dimensions: COIFFANTE SP (panels between 60 and 150mm).
Griddle Download PV 1200j
- Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).
Insulated adaptable upstand
- Adaptable upstand with 15mm thick insulation board (as standard) covered with corner-welded galvanised steel.
Manual opening
- Opening is controlled by a 1.5m, 2m, 3m or 4m long brace.
Painted griddle Download PV 1200j
- Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.
Painted upstand
- The inside of the upstand can be painted. RAL tint to be specified in the order.
Single flap
- Single-leaf device
Flat part of upstand
- 80mm flat measurements as standard. Special dimensions: COIFFANTE SP (panels between 60 and 150mm).
Griddle
- Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).
Insulated adaptable upstand
- Adaptable upstand with 15mm thick insulation board (as standard) covered with corner-welded galvanised steel.
Manual opening
- Opening is controlled by a 1.5m, 2m, 3m or 4m long brace.
Painted griddle
- Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.
Painted upstand
- The inside of the upstand can be painted. RAL tint to be specified in the order.
Single flap
- Single-leaf device