Hexadome
Fully open
Print

Daily ventilation

Devices for dry roofs / HEXAONDE Air Electrique

Daily ventilation - HEXAONDE Air Electrique
Download
HEXAONDE AIR electric is a skylight for dry roofs designed for overhead lighting and daily ventilation.

HEXAONDE AIR electric features a smoke vent built into a polyester profiled upstand reinforced with tinted fibreglass (steel or aluminium cladding: RAL 9010, fibre cement: RAL 7040).

   
ReferenceDimension (Low shafts)Dimension (High shafts)SLU m²SGOWeightAngle d'ouverture
C100120 x 120100 x 1001,001,004920
C120140 x 140120 x 1201,441,445220
C140160 x 160140 x 1401,961,966020
C160180 x 180160 x 1602,562,567520
R100-150120 x 170100 x 1501,501,505220
R100-200120 x 220100 x 2002,002,006320
R140-200160 x 220140 x 2002,802,808620

Aluminium cover

  • Insulated, light transmission = 0%, heat loss coefficient U = 1.18 W/m².K.
  • Non-insulated, light transmission = 0%.

Double dome  Download PV fire  Download PV 1200j

  • Opal/Transparent (M4), light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
  • Opal/Transparent (M4 non-dripping) light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.
  • HEXACHOC 1200 Joules, Transparent/Opal (M4 non-dripping) light transmission = 70%, heat loss coefficient U = 2,8 W/m².K.

PCA 10 mm  Download PV fire

  • Opal (B-S1 d0), light transmission = 62%, heat loss coefficient U = 3.1 W/m².K.
  • Transparent (B-S1 d0), light transmission = 85%, heat loss coefficient U = 3.1 W/m².K.
  • Calor control (B-S1 d0), light transmission = 55%, heat loss coefficient U = 3.1 W/m².K.
  • Grey opaque, light transmission = 0%, heat loss coefficient U = 3.1 W/m².K.

PCA 16 mm  Download PV fire

  • Opal (B-S2 d0), light transmission = 51%, heat loss coefficient U = 2.8 W/m².K.
  • Transparent (B-S2 d0), light transmission = 74%, heat loss coefficient U = 2.4 W/m².K.
  • Calor control (B-S2 d0), light transmission = 46%, heat loss coefficient U = 2,4 W/m².K.

Electric opening

  • 230V electric cylinder, 50 HZ, 160 W, 0.7 A, 300mm travel (on-site assembly)

Griddle  Download PV 1200j

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).

Painted griddle  Download PV 1200j

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.

Painted profiled upstand

  • The outer edge of the profiled upstand is protected by a standard RAL 9010 (white) gelcoat; optional painting in most colours in the RAL range (specify in the order).

Profile type

  • Steel cladding.

Profile type

  • Fibre cement.

Profile type

  • Sandwich cladding.

Profile type

  • Aluminium cladding.

Single flap

  • Single-leaf device

Electric opening

  • 230V electric cylinder, 50 HZ, 160 W, 0.7 A, 300mm travel (on-site assembly)

Griddle

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests).

Painted griddle

  • Cylindrical diameter 8: 150mm spacing, satisifies guidelines for the protection of personnel moving on roofs (it has passed the 1200 joules dynamic tests). RAL tint to be specified in the order.

Painted profiled upstand

  • The outer edge of the profiled upstand is protected by a standard RAL 9010 (white) gelcoat; optional painting in most colours in the RAL range (specify in the order).

Profile type

  • Aluminium cladding.
  • Fibre cement.
  • Sandwich cladding.
  • Steel cladding.

Single flap

  • Single-leaf device