Hexadome
Hexadome Soir06
Print

Daily ventilation

Louvred vents / HEXASTEEL LAME TPS

HEXASTEEL LAME TPS (CO2 opening/closing) is a smoke and heat ventilator (NSHEV) with un-insulated aluminium blades for all types of roof designed for ventilation and smoke extraction.

HEXASTEEL LAME TPS features: motorised blades powered by a pneumatic cylinder and gas springs (200mm travel). The aluminium blades pivot on an aluminium outer fixed frame and are surrounded by windshields.

   
ReferenceDimension (Low shafts)Dimension (High shafts)Number of louversUpstand AFA 280mmSGOWeight
1000-16711000 x 16711000 x 1671131,121,6769
1000-21711000 x 21711000 x 2171171,452,1781
1046-10461046 x 10461046 x 104680,731,0954
1171-11711171 x 11711171 x 117190,921,3761
1296-12961296 x 12961296 x 1296101,131,6868
1400-21711400 x 21711400 x 2171172,043,0495
1421-14211421 x 14211421 x 1421111,352,0275
1500-26711500 x 26711500 x 2671212,684,01113
1500-30461500 x 30461500 x 3046243,064,57124
1546-15461546 x 15461546 x 1546121,602,3983
1671-16711671 x 16711671 x 1671131,872,7991
1796-17961796 x 17961796 x 1796142,163,23100
1921-19211921 x 19211921 x 1921152,473,69108
2000-30462000 x 30462000 x 3046244,086,09148

No filling for this product

Aluminium blades

  • Un-insulated unwrought aluminium blades.

C02 thermofuse

  • Rated to trip at 93°C (as standard and factory-assembled, delivered with CO2 cartridge).

Painted upstand

  • The inside of the upstand can be painted. RAL tint to be specified in the order.

Pneumatic opening

  • Opening is controlled by a pneumatic cylinder.

SL 250 snow load

  • Regulatory snow load for smoke extraction in buildings located between 0 and 400m in altitude. SL 250 = 25 daN/m².

SL 500 snow load

  • Regulatory snow load for smoke extraction in buildings located between 400 and 800m in altitude. SL 500 = 50 daN/m².

Upstand for PVC membrane

  • Upstand with factory-assembled unbacked insulation board compatible with a PVC membrane. Option to attach a strip of galvanised or PVC-coated steel at the top of the skylight frame.

Aluminium blades

  • Un-insulated unwrought aluminium blades.

C02 thermofuse

  • Rated to trip at 93°C (as standard and factory-assembled, delivered with CO2 cartridge).

Painted upstand

  • The inside of the upstand can be painted. RAL tint to be specified in the order.

Pneumatic opening

  • Opening is controlled by a pneumatic cylinder.

SL 250 snow load

  • Regulatory snow load for smoke extraction in buildings located between 0 and 400m in altitude. SL 250 = 25 daN/m².

SL 500 snow load

  • Regulatory snow load for smoke extraction in buildings located between 400 and 800m in altitude. SL 500 = 50 daN/m².

Upstand for PVC membrane

  • Upstand with factory-assembled unbacked insulation board compatible with a PVC membrane. Option to attach a strip of galvanised or PVC-coated steel at the top of the skylight frame.